
816 reviews analysed
1. Robinair (15500) VacuMaster Economy Vacuum Pump – 2-Stage, 5 CFM
Feature
- Robinair’s VacuMaster Economy Vacuum Pump is designed for air conditioning and refrigeration service
- featuring a 2-stage rotary vane design, 7.5 ounce oil capacity, and non-skid feet
- 5 CFM free air displacement
- factory rated to 35 microns
- 1/3 HP, 115V/60 Hz thermally protected motor
- Features an inlet fitting engineered for maximum airflow, while preventing oil backflow, and finned aluminum surfaces that dissipate heat faster, keeping the pump cooler and extending life
- 1/4 inch MFL & 3/8 inch ACME inlet fittings, 3/8 inch FFL x 1/2 inch Acme adapter, easy to read sight glass, easy access oil fill port, and angled oil drain valve for faster, more complete draining
2. Testo 552 – Digital Vacuum/Micron Gauge with Bluetooth
3. Refrigeration Gauges Digital Manifold HVAC Gauge Set, Vacuum Pressure Temperature Leakage Tester for Testing Maintaining Air-Conditioner, Refrigerator
Feature
- Autool digital refrigeration gauges including Wording condition pressure test, Overheating test, Vacuum pressure test, Pressure leakage test, Dual-channel temperature sensor, Leakage speed hint. It is a necessary tool for testing and maintenance of refrigeration equipment such as air conditioners, fridge and cold storage.
- With double pressure test, dual temperature test, digital readout, multi-unit switching, multi-mode function and built-in refrigerant database, automatic conversion of temperature Celsius / Fahrenheit, convenient for various measurements
- Built-in 89 kinds of refrigerant pressure-evaporation temperature database, also calculate the subcooling superheat, to facilitate direct reading of operating process data. Also it tests percentage of vacuum measurement, pressure leak measurement, leak time speed record.
- Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation. Long-life valve switches, 1/4-inch standard interface design to ensure that the instrument’s durability and versatility.
- The instrument uses high-strength engineering plastic and flexible non-slip silicone design. The whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability.
Description
Compatible with Refrigerant System: R11 R13 R113 R114 R115 R116 R12 R123 R124 R125 R1270 R134A R14 R141B R142B R143A R152A R170 R21 R218 R22 R227EA R23 R236EA R245CA R245FA R290 R32 R401A R401B R401C R402A R402B R403A R403B R404A R404B R405A R406A R407A R407B R407C R407D R407E R408A R409A R41 R410A R410B R411A R411B R412A R413A R414A R414B R415A R415B R416A R417A R418A R419A R420A R421A R421B R422A R422B R422C R422D R423A R424A R425A R426A R427A R428A R50 R500 R501 R502 R503 R504 R507A R508A R508B R509A R600 R600A R717 R744(Co2) R1234
Specifications:
Pressure test: gauge pressure
Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
Pressure test range: 0 Kpa – 6000 Kpa
Pressure test resolution: 1 Kpa
Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
Vacuum test: relative vacuum
Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
Vacuum test range: -101 Kpa – 0 Kpa
Vacuum test resolution: 1 Kpa
Temperature test unit: °C (Celsius), °F (Fahrenheit)
Temperature test range: -40°C–150°C (-40°F–302°F)
Temperature test resolution:
0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
Built-in 89 kinds of refrigerant NIST: According to American NIST standard
Power Supply: 4 X 1.5V (SIZE.AA / LR6) Battery not included
Dimensions: 170*110*50mm weight: 950g
Package Includes:
1x Refrigerantion Digital Manifold Gauge
1x User Manual (in English)
2x Temperature Clip
3x Test Pipe
1x Suitcase
(Battery not included)
4. CPS VG200: Vacuum Gauge with Digital LCD Display
Feature
- ACCURATE – Calibrated to strict NIST standards for best-in-class accuracy and reliability.
- SMART DESIGN – Advanced sensor design with self-heated thermistor bridge and automatic temperature compensation.
- SIMPLE TO CLEAN – Field cleanable sensor designed to withstand 400 Psi of positive pressure.
- EASY TO READ – Continual digital readout of evacuation process on large, easy to read 5-digit LCD display.
- USER SELECTABLE UNITS – Choose between microns, torr, in/hg or mBar.
Description
The use of a vaccum gauge is essential to insure that a repaired or newly installed system is clear of contaminants. Improper evacuation can lead to costly recalls and repairs. The digital vaccum gauge measures what takes place beyond 29″ of vaccum.
5. Supco VG64 Vacuum Gauge, Digital Display, 0-12000 microns Range, 10% Accuracy, 1/4" Male Flare Fitting Connection
6. Supco VG640D Vacuum Gauge, -10% Accuracy
Description
Dual port, high resolution, fast response digital vacuum gauge provides ultimate productivity. The vacuum Sentry guards system service activity and provides notification when preset alarm thresholds are met.
7. Yellow Jacket 69080 Digital LCD Vacuum Gauge
Description
Product Description
TRACK DOWN THE 14 LEVEL BAR GRAPH FROM ATMOSPHERE TO 25 MICRONS
From the Manufacturer
Yellow Jacket 69080 Digital LCD Vacuum Gauge NEW
8. BACOENG Vacuum Pump & Manifold Gauge Set – HVAC A/C Refrigeration Kit – Diagnostic R12 R22 R134a R410A – w/Case
Feature
- Gauge Set — 2 Valve Manifold with sight-glass & 1/4″ SAE fittings anodized aluminum block body, oversized sight-glass for easy viewing the refrigerant flow high quality gauge and high accuracy of reading
- Vacuum Pump – Newly Designed Compact Vacuum Pump, Portable and Stronger. Flow rate: 3.6CFM Power: 1/4HP Ultimate Vacuum: 0.8Pa
- Accessory–3 × 4FT Blue Red Yellow Refrigrant Hose,2 × 1/4″ SAE Male to 5/16″ SAE Female Adapters(R410a), 1 × Toolkit, 12oz Vacuum Oil, 1 × Manual for Pump and Gauge
- Hose– All hose are complied with SAE-J2196 standard standard. Hose Working pressure: 800PSI-4000PSI Acceptable refrigerant: CFC HCFC and HFC
- Multi-function Gauge– Ideal for R12 R22 R134a(Need Additional Quick Couplers) R410A R407C. Pressure and Temperature Displayed.
9. AUTOOL lm120+ Refrigeration Digital Manifold Gauge Meter HVAC Vacuum Pressure Temperature Tester Kit Leakage Test with Test Clip and Pipe
Feature
- The instrument uses high-strength engineering plastics and flexible non-slip silicone design, the whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability. Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation. Long-life valve switch, 1/4-inch standard interface design to ensure that the instrument’s durability and versatility.
- The instrument can measure double pressure at the same time, as well as dual temperature measurement, with automatic multi-unit pressure conversion, automatic conversion of temperature Celsius / Fahrenheit, to facilitate different needs. Built-in 89 kinds of refrigerant pressure-evaporation temperature database, also calculate the subcooling superheat, to facilitate direct reading of operating process data.
- The instrument has double pressure test, dual temperature test , digital readout, multi-unit switching, multi-mode function and built-in refrigerant database.
- The intelligent electronic refrigerant group instrument is an auxiliary instrument for the installation, testing and maintenance of refrigeration equipment such as air conditioners,fridge and cold storage. The instrument tests percentage of vacuum measurement
- pressure leak measurement, leak time speed record. It is deserved to have this multi-functional, accurate and simply operated digital manifold let you do the job right.
- Packing list:NOTE:Battery not include. 1x Refrigerantion Digital Manifold Gauge. 1x User Manual (in English). 2x Temperature Clip. 3x Test Pipe. 1x Suitcase.
Description
Safety Standards for Design and Production:
(1) The pressure measured by the digtal manifold pressure tester is gauge pressure.
(2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).
(3) The limit pressure is 10 Mpa (100 bar).
(4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ). The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ).
(5) Please confirm the rated pressure value of the tested equipment before testing. Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed hoses does not match the pressure requirement, you can use suitable replacements for testing.
(6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.
(7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring.
Product specifications:
Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
Pressure test range: 0 Kpa – 6000 Kpa
Pressure test resolution: 1 Kpa
Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
Vacuum test: relative vacuum
Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
Vacuum test range: -101 Kpa – 0 Kpa
Vacuum test resolution: 1 Kpa
Temperature test unit: °C (Celsius), °F (Fahrenheit)
Temperature test range: -40°C–150°C (-40°F–302°F)
Temperature test resolution:
0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
Built-in 89 kinds of refrigerant NIST: According to American NIST standard
Power Supply: 4 X 1.5V (SIZE.AA / LR6) (Battery not include)
10. Elitech PG-30Pro Red Refrigeration HVAC Digital Pressure Gauge for 87+ Refrigerants with Backlight -14.5-800 PSI 1/8” NPT
Feature
- Stable and Reliable Sensor: Use temperature-compensated pressure sensor, temperature drift not exceeding ±0.04%FS/℃
- LCD Screen& Blue Backlight Display: Partition display for different measurements, direct readings for all measurements.
- Various Refrigerants Options: Built-in 87 types of normal refrigerants PT comparison table for your convenience.
- Zero Function: If deviation occurs at zero point, use ZERO button to zero out and correct the system.
- Two Overload Indication: Screen display of “Alarm” or “ALARM” & flashing backlight when overload is too high for certain levels.
Conclusion
By our suggestions above, we hope that you can found Refrigeration Vacuum Gauge Micron for you.Please don’t forget to share your experience by comment in this post. Thank you!